PCB Relay
Miniature Relay for Signal Circuits
IIIII
G5V-2
Wide switching power of 10 µA to 2 A.
High dielectric strength coil-contacts:1,000 VAC; open contacts: 750 VAC.
Conforms to FCC Part 68 requirements.
Ag + Au clad bifurcated crossbar contacts and fully sealed for high contact reliability. New 150-mW relays with high-sensitivity.
4+ FCCOrdering Information
ClassificationStandardHigh-sensitivity
Contact formDPDT
Contact typeBifurcated crossbar
Contact materialAg + Au-clad
Enclosure ratingsFully sealed
G5V-2G5V-2-H1
Model
Note: When ordering, add the rated coil voltage to the model number.Example: G5V-2 12 VDCRated coil voltageModel Number Legend
G5V - - VDC1231. Contact Form 2: DPDT2. Classification H1: High-sensitivity3. Rated Coil Voltage 3, 5, 6, 9, 12, 24, 48 VDCSpecifications
I
Coil Ratings
3 VDC166.7 mA18 W
Armature OFFArmature ON
0.040.05
5 VDC100 mA50 W0.090.11
6 VDC83.3 mA72 W0.160.19
9 VDC55.6 mA162 W0.310.49
12 VDC41.7 mA288 W0.470.74
24 VDC20.8 mA1,152 W1.982.63
48 VDC12 mA4,000 W7.2310.00
Standard Models
Rated voltageRated currentCoil resistanceCoil inductance(H) (ref. value)
Must operate voltageMust release voltageMax. voltagePower consumption
75% max. of rated voltage5% min. of rated voltage120% of rated voltage at 23°CApprox. 500 mW
Approx. 580mW
1
元器件交易网www.cecb2b.com
G5V-2G5V-2High Sensitivity Models
Rated voltageRated currentCoil resistanceCoil inductance(H) (ref. value)
Armature ONArmature OFF
3 VDC50 mA60 W0.180.57
5 VDC30 mA166.7 W0.460.71
6 VDC25 mA240 W0.700.97
9 VDC16.7 mA540 W1.672.33
12 VDC12.5 mA960 W2.903.99
24 VDC8.33 mA2,880 W6.729.27
48 VDC6.25 mA7,680 W20.126.7
Must operate voltageMust release voltageMax. voltagePower consumptionNote:I
75% max. of rated voltage5% min. of rated voltage180% of rated voltage at 23°CApprox. 150 mW
Approx. 200mW
150% of rated voltage at 23°CApprox. 300mW
1.The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.2.Operating characteristics are measured at a coil temperature of 23°C.
Contact Ratings
Item
Standard models
Resistive load (cosf = 1)0.5 A at 125 VAC; 2 A at 30 VDCAg + Au-clad2 A
125 VAC, 125 VDC2 A
62.5 VA, 60 W0.01 mA at 10 mVDC
1 A
62.5 VA, 24 W
0.5 A at 125 VAC; 1 A at 24 VDC
High sensitivity models
LoadRated loadContact materialRated carry currentMax. switching voltageMax. switching currentMax. switching powerFailure rate (reference value)NoteI
Note:P level: l60 = 0.1 x 10–6/operation
Characteristics
Item
Standard models
50 mW max.7 ms max.3 ms max.
Operate: approx. 0.3 msRelease: approx. 1.5 ms
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)1,000 MW min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between con-tacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between con-tacts of different polarity
500 VAC, 50/60 Hz for 1 min between contacts of same polarity
High sensitivity models
100 mW max.
Contact resistanceOperate timeRelease timeBounce time
Max. operating frequencyInsulation resistanceDielectric strength
Impulse withstand voltageVibration resistanceShock resistanceEndurance
Ambient temperatureAmbient humidityWeight
1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)Destruction: 1,000 m/s2 (approx. 100G)Malfunction: 200 m/s2 (approx. 20G)
Destruction: 1,000 m/s2 (approx. 100G)Malfunction: 100 m/s2 (approx. 10G)
Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)Electrical: 100,000 operations min. (at 1,800 operations/hr)Operating: -25°C to 65°C (with no icing)Operating: 5% to 85%Approx. 5 g
Operating: -25°C to 70°C (with no icing)
2
元器件交易网www.cecb2b.com
G5V-2I
G5V-2Approved Standards
Contact form
Coil ratings
G5V-2
3 to 48 VDC
0.6 A, 125 VAC (general use)0.6 A, 110 VDC (resistive load)2 A, 30 VDC (resistive load)
Contact ratings
G5V-2-H1
0.5 A, 125 VAC (general use)0.2 A, 110 VDC (resistive load)1 A, 24 VDC (resistive load)
UL478, UL1950, UL508 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR24825)
DPDT
Engineering Data
Maximum Switching Power
G5V-2
)AAC resistive load( tDC rensistiveerloadruc gnihctiwSSwitching voltage (V)
G5V-2-H1
53)A( AC resistive tnloader1ru0.7c g0.5nihc0.3DC resistive loadtiw0.2S0.10Switching voltage (V)3
Endurance
Ambient Temperature vs. G5V-2Maximum Coil Voltage
G5V-2
)sno)ita30-VDC reresistive %( loadeCoil rated voltagepg3 to 24 VDCoa t l 30o1v xli(o ec125-VAC resistive c48 VDCnloadmaurumidxnaEM123Switching current (A)Ambient temperature (°)
Note: The maximum coil voltage refers to the maxi-mum value in a varying range of operating power voltage, not a continuous voltage.
G5V-2-H1
G5V-2-H1
1000200)sn50024-VDC resistive load)3 to 24 VDCoi%180ta300( reeg160paotl 3 0100125-VAC resistive loadov140 1lixo( 50c ycm12048 VDCn30uatmi100cxeap10M80ex efiL0Switching current (A)Ambient temperature (°)
Note: The maximum coil voltage refers to the maxi-mum value in a varying range of operating power voltage, not a continuous voltage.
元器件交易网www.cecb2b.com
G5V-2G5V-2Dimensions
Note:
1.All units are in millimeters unless otherwise indicated.2.Orientation marks are indicated as follows: Terminal Arrangement/Internal Connections (Bottom View)18(1.3)Mounting Holes(Bottom View)Tolerance: ±0.17.625.085.08(1.2)7.6220.5 max.20.3 typ.10.1 max.9.9 typ.1611.5 max.4611139(1.3)11.4 typ.Eight, 1-dia. holes0.50.50.37.623.5ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K046-E1-2B
4