搜索
您的当前位置:首页正文

G5V-212VDC资料

来源:知库网
元器件交易网www.cecb2b.com

PCB Relay

Miniature Relay for Signal Circuits

IIIII

G5V-2

Wide switching power of 10 µA to 2 A.

High dielectric strength coil-contacts:1,000 VAC; open contacts: 750 VAC.

Conforms to FCC Part 68 requirements.

Ag + Au clad bifurcated crossbar contacts and fully sealed for high contact reliability. New 150-mW relays with high-sensitivity.

4+ FCCOrdering Information

ClassificationStandardHigh-sensitivity

Contact formDPDT

Contact typeBifurcated crossbar

Contact materialAg + Au-clad

Enclosure ratingsFully sealed

G5V-2G5V-2-H1

Model

Note: When ordering, add the rated coil voltage to the model number.Example: G5V-2 12 VDCRated coil voltageModel Number Legend

G5V - - VDC1231. Contact Form 2: DPDT2. Classification H1: High-sensitivity3. Rated Coil Voltage 3, 5, 6, 9, 12, 24, 48 VDCSpecifications

I

Coil Ratings

3 VDC166.7 mA18 W

Armature OFFArmature ON

0.040.05

5 VDC100 mA50 W0.090.11

6 VDC83.3 mA72 W0.160.19

9 VDC55.6 mA162 W0.310.49

12 VDC41.7 mA288 W0.470.74

24 VDC20.8 mA1,152 W1.982.63

48 VDC12 mA4,000 W7.2310.00

Standard Models

Rated voltageRated currentCoil resistanceCoil inductance(H) (ref. value)

Must operate voltageMust release voltageMax. voltagePower consumption

75% max. of rated voltage5% min. of rated voltage120% of rated voltage at 23°CApprox. 500 mW

Approx. 580mW

1

元器件交易网www.cecb2b.com

G5V-2G5V-2High Sensitivity Models

Rated voltageRated currentCoil resistanceCoil inductance(H) (ref. value)

Armature ONArmature OFF

3 VDC50 mA60 W0.180.57

5 VDC30 mA166.7 W0.460.71

6 VDC25 mA240 W0.700.97

9 VDC16.7 mA540 W1.672.33

12 VDC12.5 mA960 W2.903.99

24 VDC8.33 mA2,880 W6.729.27

48 VDC6.25 mA7,680 W20.126.7

Must operate voltageMust release voltageMax. voltagePower consumptionNote:I

75% max. of rated voltage5% min. of rated voltage180% of rated voltage at 23°CApprox. 150 mW

Approx. 200mW

150% of rated voltage at 23°CApprox. 300mW

1.The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.2.Operating characteristics are measured at a coil temperature of 23°C.

Contact Ratings

Item

Standard models

Resistive load (cosf = 1)0.5 A at 125 VAC; 2 A at 30 VDCAg + Au-clad2 A

125 VAC, 125 VDC2 A

62.5 VA, 60 W0.01 mA at 10 mVDC

1 A

62.5 VA, 24 W

0.5 A at 125 VAC; 1 A at 24 VDC

High sensitivity models

LoadRated loadContact materialRated carry currentMax. switching voltageMax. switching currentMax. switching powerFailure rate (reference value)NoteI

Note:P level: l60 = 0.1 x 10–6/operation

Characteristics

Item

Standard models

50 mW max.7 ms max.3 ms max.

Operate: approx. 0.3 msRelease: approx. 1.5 ms

Mechanical: 36,000 operations/hr

Electrical: 1,800 operations/hr (under rated load)1,000 MW min. (at 500 VDC)

1,000 VAC, 50/60 Hz for 1 min between coil and contacts

1,000 VAC, 50/60 Hz for 1 min between con-tacts of different polarity

750 VAC, 50/60 Hz for 1 min between contacts of same polarity

1,000 VAC, 50/60 Hz for 1 min between coil and contacts

1,000 VAC, 50/60 Hz for 1 min between con-tacts of different polarity

500 VAC, 50/60 Hz for 1 min between contacts of same polarity

High sensitivity models

100 mW max.

Contact resistanceOperate timeRelease timeBounce time

Max. operating frequencyInsulation resistanceDielectric strength

Impulse withstand voltageVibration resistanceShock resistanceEndurance

Ambient temperatureAmbient humidityWeight

1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)

Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)Destruction: 1,000 m/s2 (approx. 100G)Malfunction: 200 m/s2 (approx. 20G)

Destruction: 1,000 m/s2 (approx. 100G)Malfunction: 100 m/s2 (approx. 10G)

Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)Electrical: 100,000 operations min. (at 1,800 operations/hr)Operating: -25°C to 65°C (with no icing)Operating: 5% to 85%Approx. 5 g

Operating: -25°C to 70°C (with no icing)

2

元器件交易网www.cecb2b.com

G5V-2I

G5V-2Approved Standards

Contact form

Coil ratings

G5V-2

3 to 48 VDC

0.6 A, 125 VAC (general use)0.6 A, 110 VDC (resistive load)2 A, 30 VDC (resistive load)

Contact ratings

G5V-2-H1

0.5 A, 125 VAC (general use)0.2 A, 110 VDC (resistive load)1 A, 24 VDC (resistive load)

UL478, UL1950, UL508 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR24825)

DPDT

Engineering Data

Maximum Switching Power

G5V-2

)AAC resistive load( tDC rensistiveerloadruc gnihctiwSSwitching voltage (V)

G5V-2-H1

53)A( AC resistive tnloader1ru0.7c g0.5nihc0.3DC resistive loadtiw0.2S0.10Switching voltage (V)3

Endurance

Ambient Temperature vs. G5V-2Maximum Coil Voltage

G5V-2

)sno)ita30-VDC reresistive %( loadeCoil rated voltagepg3 to 24 VDCoa t l 30o1v xli(o ec125-VAC resistive c48 VDCnloadmaurumidxnaEM123Switching current (A)Ambient temperature (°)

Note: The maximum coil voltage refers to the maxi-mum value in a varying range of operating power voltage, not a continuous voltage.

G5V-2-H1

G5V-2-H1

1000200)sn50024-VDC resistive load)3 to 24 VDCoi%180ta300( reeg160paotl 3 0100125-VAC resistive loadov140 1lixo( 50c ycm12048 VDCn30uatmi100cxeap10M80ex efiL0Switching current (A)Ambient temperature (°)

Note: The maximum coil voltage refers to the maxi-mum value in a varying range of operating power voltage, not a continuous voltage.

元器件交易网www.cecb2b.com

G5V-2G5V-2Dimensions

Note:

1.All units are in millimeters unless otherwise indicated.2.Orientation marks are indicated as follows: 󰀁Terminal Arrangement/Internal Connections (Bottom View)18(1.3)Mounting Holes(Bottom View)Tolerance: ±0.17.625.085.08(1.2)7.6220.5 max.20.3 typ.10.1 max.9.9 typ.1611.5 max.4611139(1.3)11.4 typ.Eight, 1-dia. holes0.50.50.37.623.5ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. K046-E1-2B

4